Schneider G12F3F50 | Circuit breaker, GoPact MCCB 125, 3 poles, 30kA at 415VAC, 50A rating, TMD trip unit, fixed thermal protection
- Brand: Schneider
- SKU: G12F3F50
3,878 EGP7,863 EGP (-51%)
2 in stock
Schneider G12F3F50 | Circuit breaker, GoPact MCCB 125, 3 poles, 30kA at 415VAC, 50A rating, TMD trip unit, fixed thermal protection
Outline of the Article
- Introduction to Schneider G12F3F50
- Understanding Circuit Breakers
- Overview of GoPact MCCB 125
- Specifications of Schneider G12F3F50
- Importance of 3 Poles in Circuit Breakers
- Explaining 30kA at 415VAC Rating
- Features of the 50A Rating
- Functionality of TMD Trip Unit
- Significance of Fixed Thermal Protection
- Application Areas of Schneider G12F3F50
- Comparing Schneider G12F3F50 with other Circuit Breakers
- Maintenance and Safety Tips
- Advantages of Using Schneider G12F3F50
- Future Developments in Circuit Breaker Technology
- Conclusion
Schneider G12F3F50 | Circuit breaker, GoPact MCCB 125, 3 poles, 30kA at 415VAC, 50A rating, TMD trip unit, fixed thermal protection description
Introduction to Schneider G12F3F50
The Schneider G12F3F50 is a high-quality circuit breaker designed to meet the demanding needs of modern electrical systems. It falls under the GoPact MCCB 125 series, offering reliable protection for various electrical applications.
Understanding Circuit Breakers
Circuit breakers are essential components in electrical systems, serving as safety devices that automatically interrupt electrical flow when an overload or short circuit occurs. They prevent damage to equipment and ensure safety for users.
Overview of GoPact MCCB 125
The GoPact MCCB 125 series by Schneider Electric is known for its robustness and efficiency in handling electrical faults. It combines advanced technology with durable construction to deliver superior performance.
Specifications of Schneider G12F3F50
The Schneider G12F3F50 is a 3-pole circuit breaker with a high breaking capacity of 30kA at 415VAC. It has a rated current of 50A, making it suitable for medium to heavy-duty applications.
Importance of 3 Poles in Circuit Breakers
The 3-pole configuration in circuit breakers like the Schneider G12F3F50 allows for effective three-phase protection, ensuring balanced load distribution and minimizing the risk of electrical faults.
Explaining 30kA at 415VAC Rating
The 30kA breaking capacity at 415VAC indicates the maximum fault current that the circuit breaker can safely interrupt without causing damage. This high rating makes the Schneider G12F3F50 suitable for industrial settings with demanding electrical loads.
Features of the 50A Rating
The 50A rated current of the Schneider G12F3F50 reflects its capacity to handle continuous currents up to 50 amps, making it ideal for applications requiring moderate to high power consumption.
Functionality of TMD Trip Unit
The TMD trip unit in the Schneider G12F3F50 provides precise and reliable tripping characteristics based on thermal and magnetic principles, ensuring swift response to electrical faults while minimizing nuisance trips.
Significance of Fixed Thermal Protection
The fixed thermal protection feature in this circuit breaker offers additional safety by monitoring temperature rise and tripping the unit if it detects overheating, thereby preventing damage to the electrical system.
Application Areas of Schneider G12F3F50
The Schneider G12F3F50 finds extensive use in industrial, commercial, and residential settings where reliable circuit protection is crucial. It is commonly deployed in distribution boards, motor control centers, and power distribution systems.
Comparing Schneider G12F3F50 with other Circuit Breakers
When compared to standard circuit breakers, the Schneider G12F3F50 stands out due to its superior performance metrics, advanced trip unit technology, and robust construction, making it a preferred choice for critical applications.
Maintenance and Safety Tips
Regular maintenance and adherence to safety protocols are essential for maximizing the lifespan and efficiency of the Schneider G12F3F50. Inspections, testing, and proper installation play key roles in ensuring optimal performance and safety.
Advantages of Using Schneider G12F3F50
- High breaking capacity for enhanced safety
- Precise trip unit functionality for reliable protection
- Durable construction for long-term reliability
- Wide applicability across diverse electrical systems
- Compliance with industry standards for safety and performance
Future Developments in Circuit Breaker Technology
The field of circuit breaker technology continues to evolve, with ongoing advancements focusing on enhanced performance, intelligent monitoring, and integration with digital systems for predictive maintenance and real-time diagnostics.
Conclusion
In conclusion, the Schneider G12F3F50 circuit breaker from Schneider Electric offers a comprehensive solution for efficient and reliable circuit protection. Its advanced features, high performance metrics, and wide applicability make it a top choice for various electrical applications.
FAQs
- What is the main function of a circuit breaker like Schneider G12F3F50? Circuit breakers like the Schneider G12F3F50 are designed to interrupt electrical flow in case of overloads or short circuits, thereby protecting electrical systems and equipment.
- What does the 3-pole configuration in Schneider G12F3F50 offer? The 3-pole configuration provides effective three-phase protection, ensuring balanced load distribution and minimizing electrical faults.
- How does the TMD trip unit in Schneider G12F3F50 work? The TMD trip unit operates based on thermal and magnetic principles to detect electrical faults and trip the circuit breaker, offering precise and reliable protection.
- Where is the Schneider G12F3F50 commonly used? This circuit breaker is commonly used in industrial, commercial, and residential settings where reliable circuit protection is essential, such as distribution boards and motor control centers.
- What are the advantages of using Schneider G12F3F50 over standard circuit breakers? The advantages include high breaking capacity, precise trip unit functionality, durability, wide applicability, and compliance with industry standards.
Additional information
brands | Schneider Electric |
---|---|
Product or component type | Circuit breaker |
Product name | GoPact MCCB 125 |
Range of product | GoPact MCCB |
Device application | Distribution |
Protected poles description | 3D |
[In] rated current | 50 A at 40 °C |
Performance level | F 30 kA 380/415 V AC |
Trip unit name | TM-D |
Trip unit technology | Thermal-magnetic |
Circuit breaker mounting mode | |
Mechanical durability | 30000 cycles |
30000 cycles | |
Mounting support | Backplate |
Mounting position | Horizontal and vertical Flat on the back |
Upside connection | |
downside connection | |
Connection terminals | |
Connection pitch | 25 mm |
Trip unit rating | |
Colour | Grey (RAL 7035) |
Poles description | 3P |
Mounting mode | Fixed |
Utilisation category | Category A |
Net weight | 0.7 kg |
Overvoltage category | III |
Pollution degree | 3 conforming to IEC 60664-1 |
Height | 130 mm |
Width | 75 mm |
Depth | 60 mm |
Unit Type of Package 1 | PCE |
Number of Units in Package 1 | 1 |
Package 1 Height | 12.4 cm |
Package 1 Width | 8.5 cm |
Package 1 Length | 13.9 cm |
Package 1 Weight | 908 g |
Unit Type of Package 2 | S02 |
Number of Units in Package 2 | 8 |
Package 2 Height | 15 cm |
Package 2 Width | 30 cm |
Package 2 Length | 40 cm |
Package 2 Weight | 7.579 kg |
Unit Type of Package 3 | P06 |
Number of Units in Package 3 | 128 |
Package 3 Height | 75 cm |
Package 3 Width | 60 cm |
Package 3 Length | 80 cm |
Package 3 Weight | 129.764 kg |
Sustainable offer status | Green Premium product |
REACh Regulation | REACh Declaration |
EU RoHS Directive | Compliant EU RoHS Declaration |
Mercury free | Yes |
China RoHS Regulation | China RoHS declaration Product out of China RoHS scope. Substance declaration for your information |
RoHS exemption information | Yes |
Environmental Disclosure | Product Environmental Profile |
Circularity Profile | End of Life Information |
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
PVC free | Yes |