Schneider LC1D12Q7 Contactor | TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 12 A – 380 V AC coil

1,548 EGP2,867 EGP (-46%)

20 in stock

Schneider LC1D12Q7 Contactor

Schneider LC1D12Q7 Contactor: Enhancing Electrical Control

is a vital component in electrical systems, playing a crucial role in controlling the flow of electricity. Whether you’re a seasoned electrician or a DIY enthusiast, understanding the ins and outs of this contactor can significantly benefit your projects. In this comprehensive guide, we’ll delve into the features, installation process, benefits, applications, maintenance, and troubleshooting of the Schneider LC1D12Q7 Contactor.

Understanding the Functionality of Contactors

Contactors are electromechanical switches designed to control the flow of electricity in a circuit. They consist of a coil, contacts, and an enclosure. When energized, the coil generates a magnetic field, attracting the contacts and closing the circuit. Conversely, when the coil is de-energized, the contacts open, interrupting the flow of electricity.

Features and Specifications of Schneider LC1D12Q7 Contactor

The Schneider LC1D12Q7 Contactor boasts a myriad of features tailored for optimal performance and reliability. With a rated operational current of 12A and a coil voltage of 24VAC, this contactor is suitable for a wide range of applications. Its compact design and DIN rail mounting make installation a breeze, saving time and effort for electricians.

Installation Guide

is straightforward, provided you adhere to the manufacturer’s guidelines. Begin by ensuring the power supply is disconnected to prevent any accidents. Mount the contactor on a suitable surface using the designated mounting holes. Next, wire the control circuit to the contactor following the wiring diagram provided in the manual. Once everything is connected, restore power and test the functionality of the contactor.

Benefits

The Schneider LC1D12Q7 Contactor offers several benefits, making it a preferred choice for electrical contractors and engineers. Its reliable performance ensures smooth operation, reducing downtime and maintenance costs. Additionally, its compact design saves valuable space in electrical panels, making it ideal for applications with limited real estate.

Common Applications

From industrial machinery to HVAC systems, the Schneider LC1D12Q7 Contactor finds widespread use across various industries. Its versatility and robust construction make it suitable for controlling motors, pumps, compressors, and lighting circuits. Whether you’re building a new facility or upgrading an existing one, this contactor is sure to meet your electrical control needs.

Maintenance Tips for Schneider LC1D12Q7 Contactor

To ensure optimal performance and longevity, regular maintenance of the Schneider LC1D12Q7 Contactor is essential. Periodically inspect the contacts for signs of wear or corrosion and clean them if necessary. Tighten any loose connections and replace damaged components promptly. Lubricate moving parts to prevent friction and ensure smooth operation.

Troubleshooting Guide for Schneider LC1D12Q7 Contactor

In the event of malfunctions or operational issues, refer to the troubleshooting guide provided in the user manual. Common problems such as contact welding or coil failure can often be resolved with simple troubleshooting steps. If the issue persists, contact Schneider Electric’s customer support for assistance.

Safety Measures Associated with Schneider LC1D12Q7 Contactor

When working with electrical equipment, safety should always be a top priority. Before handling the Schneider LC1D12Q7 Contactor, ensure the power supply is disconnected and follow proper lockout/tagout procedures. Wear appropriate personal protective equipment, such as insulated gloves and safety glasses, to prevent accidents.

Comparison with Other Contactor Models

To help you make an informed decision, compare the Schneider LC1D12Q7 Contactor with other models available in the market. Consider factors such as price, features, reliability, and customer reviews to determine which contactor best suits your requirements.

Additional information

brands

Schneider Electric

Product or component type

Contactor

Range of product

TeSys Deca

Device short name

LC1D

contactor application

Resistive load Motor control

Utilisation category

AC-1 AC-4 AC-3 AC-3e

Poles description

3P

[Ie] rated operational current

25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 12 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 12 A (at <60 °C) at <= 440 V AC AC-3e for power circuit

Motor power kW

3 kW at 220…230 V AC 50/60 Hz (AC-3) 5.5 kW at 380…400 V AC 50/60 Hz (AC-3) 5.5 kW at 415…440 V AC 50/60 Hz (AC-3) 7.5 kW at 500 V AC 50/60 Hz (AC-3) 7.5 kW at 660…690 V AC 50/60 Hz (AC-3) 3.

Motor power hp

0.5 hp at 115 V AC 50/60 Hz for 1 phase motors 2 hp at 230/240 V AC 50/60 Hz for 1 phase motors 3 hp at 200/208 V AC 50/60 Hz for 3 phases motors 3 hp at 230/240 V AC 50/60 Hz for 3 phases motors 7.5

Compatibility code

LC1D

Pole contact composition

3 NO

Contact compatibility

M2

Protective cover

With

Irms rated making capacity

250 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1

Rated breaking capacity

250 A at 440 V for power circuit conforming to IEC 60947

Associated fuse rating

10 A gG for signalling circuit conforming to IEC 60947-5-1 40 A gG at <= 690 V coordination type 1 for power circuit 25 A gG at <= 690 V coordination type 2 for power circuit

Average impedance

2.5 mOhm – Ith 25 A 50 Hz for power circuit

Power dissipation per pole

0.36 W AC-3 1.56 W AC-1 0.36 W AC-3e

[Ui] rated insulation voltage

Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA

Overvoltage category

III

Pollution degree

3

Safety reliability level

B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1

Mechanical durability

15 Mcycles

15 Mcycles

2 Mcycles 12 A AC-3 at Ue <= 440 V 0.8 Mcycles 25 A AC-1 at Ue <= 440 V 2 Mcycles 12 A AC-3e at Ue <= 440 V

Control circuit type

AC at 50/60 Hz

Coil technology

Without built-in suppressor module

Inrush power in VA

70 VA 60 Hz cos phi 0.75 (at 20 °C) 70 VA 50 Hz cos phi 0.75 (at 20 °C)

Heat dissipation

2…3 W at 50/60 Hz

Operating time

12…22 ms closing 4…19 ms opening

Maximum operating rate

3600 cyc/h 60 °C

Tightening torque

Power circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm Power circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2 Control circuit: 1.7 N.m – on screw

Auxiliary contact composition

Auxiliary contacts type

Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1

Signalling circuit frequency

minimum switching voltage

17 V for signalling circuit

Minimum switching current

5 mA for signalling circuit

Insulation resistance

> 10 MOhm for signalling circuit

Non-overlap time

1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact

Product certifications

CSA DNV BV GL UL CCC GOST RINA LROS (Lloyds register of shipping) UKCA

Climatic withstand

Conforming to IACS E10 exposure to damp heat conforming to IEC 60947-1 Annex Q category D exposure to damp heat

Operating altitude

0…3000 m

Fire resistance

850 °C conforming to IEC 60695-2-1

Flame retardance

V1 conforming to UL 94

Height

77 mm

Width

45 mm

Depth

86 mm

Net weight

0.325 kg

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

5.5 cm

Package 1 Width

9.5 cm

Package 1 Length

11.2 cm

Package 1 Weight

351 g

Unit Type of Package 2

S02

Number of Units in Package 2

20

Package 2 Height

15 cm

Package 2 Width

30 cm

Package 2 Length

40 cm

Package 2 Weight

7.327 kg

Sustainable offer status

Green Premium product

REACh Regulation

REACh Declaration

EU RoHS Directive

Compliant EU RoHS Declaration

Mercury free

Yes