Schneider RE17RLMU | Asymmetrical flashing relay – 1 s..100 h – 24..240 V AC – 1 OC

1,501 EGP2,588 EGP (-42%)

Out of stock

Schneider RE17RLMU | Asymmetrical flashing relay – 1 s..100 h – 24..240 V AC – 1 OC

Introduction

The Schneider RE17RLMU is a cutting-edge asymmetrical flashing relay designed to provide precise control over timing functions in electrical circuits. Its versatility and reliability make it a preferred choice among professionals in the electrical engineering field.

Functionality

This relay operates by alternating the on/off cycle of a connected electrical load, allowing for customizable flashing intervals ranging from 1 second to 100 hours. This level of control is vital in applications where precise timing is required, such as industrial automation, lighting systems, and equipment monitoring.

Technical Specs

The RE17RLMU supports a wide voltage range from 24V AC to 240V AC, with a single output contact (1 OC) for seamless integration into diverse circuit setups. Its compact design and DIN rail mounting make it suitable for both new installations and retrofitting projects.

Applications

This relay finds extensive use in scenarios where intermittent operation or flashing signals are necessary. Examples include traffic signal control, elevator systems, conveyor belts, and HVAC (Heating, Ventilation, and Air Conditioning) units.

Advantages

One of the key advantages of the Schneider RE17RLMU is its ability to enhance energy efficiency by controlling the duration of electrical loads. This not only reduces power consumption but also extends the lifespan of connected devices.

Installation

Installing the RE17RLMU relay is straightforward, thanks to its user-friendly design and clear labeling of terminals. However, it is crucial to follow manufacturer guidelines and safety protocols during installation to ensure optimal performance and safety.

Troubleshooting

Despite its reliability, occasional issues may arise with the RE17RLMU relay. Common problems include erratic flashing patterns or failure to operate as expected. Troubleshooting steps may involve checking wiring connections, power supply integrity, and programming settings.

Maintenance

Regular maintenance is essential to keep the Schneider RE17RLMU relay operating smoothly. This includes periodic inspection of connections, cleaning of terminals, and updating firmware if applicable. Proper maintenance not only prevents downtime but also prolongs the relay’s lifespan.

Conclusion

In conclusion, the Schneider RE17RLMU asymmetrical flashing relay offers a sophisticated solution for precise timing control in electrical systems. Its advanced features, ease of installation, and versatility make it a valuable asset across various industries.

FAQs

  1. Can the flashing interval of the RE17RLMU be adjusted on the fly?
    • No, the flashing interval needs to be programmed beforehand using the relay’s settings.
  2. Is the RE17RLMU suitable for outdoor applications?
    • Yes, it is designed to withstand a wide temperature range and is suitable for outdoor use with proper protection.
  3. What is the typical lifespan of the RE17RLMU relay?
    • With regular maintenance and proper usage, the relay can last for several years.
  4. Can multiple RE17RLMU relays be synchronized for coordinated flashing operations?
    • Yes, multiple relays can be synchronized for synchronized flashing sequences.
  5. Does the RE17RLMU have built-in surge protection?
    • Yes, it is equipped with surge protection to safeguard against electrical spikes and surges.

Additional information

brands

Schneider Electric

Range of product

Harmony Timer Relays

Product or component type

Dual function relay

Device short name

RE17R

Time delay range

1…10 h 1…10 s 0.1…1 s 6…60 min 1…10 min 10…100 h 6…60 s

Control type

Selector switch front panel

supply voltage frequency

50…60 Hz +/- 5 %

Housing material

Self-extinguishing

Mechanical durability

10000000 cycles

Power on delay

100 ms

Safety reliability data

MTTFd = 296.8 years B10d = 270000

Width

17.5 mm

Net weight

0.07 kg

Release input voltage

10 V

Creepage distance

4 kV/3 conforming to IEC 60664-1

On-load factor

100%

Marking

CE

discrete output type

Relay

Contacts material

Cadmium free

Height

90 mm

Depth

72 mm

Contacts type and composition

Control signal pulse width

100 ms with load in parallel typical 30 ms typical

Reset time

120 ms on de-energisation typical

operating frequency

10 Hz

Time delay type

L, Li

Functionality

Asymmetrical flashing timer

Compatibility code

RE17

Nominal output current

8:00 AM

Standards

2006/95/EC IEC 61000-6-2 IEC 61000-6-4 2004/108/EC IEC 61812-1 IEC 61000-6-3 IEC 61000-6-1

Product certifications

GL cULus CSA

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

2.8 cm

Package 1 Width

7.8 cm

Package 1 Length

9.6 cm

Package 1 Weight

81.0 g

Unit Type of Package 2

S02

Number of Units in Package 2

40

Package 2 Height

15.0 cm

Package 2 Width

30.0 cm

Package 2 Length

40.0 cm

Package 2 Weight

3.68 kg

Sustainable offer status

Green Premium product

REACh Regulation

REACh Declaration

EU RoHS Directive

Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration

Mercury free

Yes

China RoHS Regulation

China RoHS declaration

China RoHS declaration

Yes

Environmental Disclosure

Product Environmental Profile

Circularity Profile

End of Life Information

Be the first to review “Schneider RE17RLMU | Asymmetrical flashing relay – 1 s..100 h – 24..240 V AC – 1 OC”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

See It Styled On Instagram

    No access token

Main Menu